- -41%

Hantek 6074BE 4 csatornás, 70 MHz-es sávszélességű autóipari oszcilloszkóp digitális USB portré Osciloscopio
Hantek 6074BE 4 csatornás, 70 MHz-es sávszélességű autóipari oszcilloszkóp digitális USB portré Osciloscopio
17 125 Ft
41% megtakarítás
29 025 Ft
Nincs adó
Hantek 6074BE 4 Channels 70Mhz Bandwidth Automotive Osiclloscope Digital USB Portrail Osciloscopio Diagnostic-tool
Standard equipped of automotive measurement function;
First Diagnosis: Intake manifold vacuum & ignition,Petrol fumes adjusting valve vacuum & ignition,Idle exhaust ignition, Starting exhaust ignition
Ignition: primary and secondary
Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
Performer: Petrol/Diesel
Starter and charging circuits
Fit for the portable computers, table PC, and suitable for wild mobile use and business trip use. Support WIN10/ WIN8/WIN7 etc.
USB 2.0 interface plug and play, and no need extra power supply;
Great function, More than 20 kinds of automatic measurement function, PASS/FAIL Check function. Resourceful trigger function, dynamic cursor tracking, waveform record and replay function.
Good mechanical design with small size which is easy for carrying. The outer case is made by the same material with iPad - Anodised aluminium. It has great heat resistance and abrasive resistance with beautiful appearance. The hardness of aluminium alloy surface is greatly improved.
4 isolated channels oscilloscope, 1GSa/s real time sampling rate, 2mV-10V/DIV high input sensitivity and large input range, 70MHz high bandwidth,
The waveform data could be output to EXCEL,BMP,JPG.
Waveform averaging, afterglow, lightness control, reverse, add, subtract, multiply, divide, X-Y display. FFT spectrum analyzer
One computer could connect with multiple oscilloscopes, expand the channel number easily.
Provide secondary development library DLL; Provide Labview\VB\VC\QT developing examples
Accessory:
HT307*1,HT19*1,HT18A*1,HT30A*1,gator clip lines*3,HT25*1,USB,CD,Manual
Model
Hantek6074BE
Bandwidth
70MHz
Channel
4 CH
Real-time Sampling Rate
1GSa/s
Memory Depth
64K
Time BasePrecision
±50ppm
Time Base Range
2ns/div-1000s/div (1-2-4 sequences)
Input Impedance
1MΩ 25pF
Input Sensitivity
2mV/div~10V/div
Vertical Resolution
8Bit
Vertical Displacement Range
2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe;
200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy
±3%
Bandwidth
20MHz
Trigger Mode
Edge, Pulse, Video, Alternative
Trigger Source
CH1, CH2, CH3,CH4
Waveform Signal Process
,-,x,÷,FFT, Invert
Cursors Measurement
Cross, Trace, Horizontal, Vertical
Auto Measurement
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume
175mm * 105mm * 25mm
Weight
0.9KG
Standard equipped of automotive measurement function;
First Diagnosis: Intake manifold vacuum & ignition,Petrol fumes adjusting valve vacuum & ignition,Idle exhaust ignition, Starting exhaust ignition
Ignition: primary and secondary
Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
Performer: Petrol/Diesel
Starter and charging circuits
Fit for the portable computers, table PC, and suitable for wild mobile use and business trip use. Support WIN10/ WIN8/WIN7 etc.
USB 2.0 interface plug and play, and no need extra power supply;
Great function, More than 20 kinds of automatic measurement function, PASS/FAIL Check function. Resourceful trigger function, dynamic cursor tracking, waveform record and replay function.
Good mechanical design with small size which is easy for carrying. The outer case is made by the same material with iPad - Anodised aluminium. It has great heat resistance and abrasive resistance with beautiful appearance. The hardness of aluminium alloy surface is greatly improved.
4 isolated channels oscilloscope, 1GSa/s real time sampling rate, 2mV-10V/DIV high input sensitivity and large input range, 70MHz high bandwidth,
The waveform data could be output to EXCEL,BMP,JPG.
Waveform averaging, afterglow, lightness control, reverse, add, subtract, multiply, divide, X-Y display. FFT spectrum analyzer
One computer could connect with multiple oscilloscopes, expand the channel number easily.
Provide secondary development library DLL; Provide Labview\VB\VC\QT developing examples
Accessory:
HT307*1,HT19*1,HT18A*1,HT30A*1,gator clip lines*3,HT25*1,USB,CD,Manual
Model
Hantek6074BE
Bandwidth
70MHz
Channel
4 CH
Real-time Sampling Rate
1GSa/s
Memory Depth
64K
Time BasePrecision
±50ppm
Time Base Range
2ns/div-1000s/div (1-2-4 sequences)
Input Impedance
1MΩ 25pF
Input Sensitivity
2mV/div~10V/div
Vertical Resolution
8Bit
Vertical Displacement Range
2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe;
200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy
±3%
Bandwidth
20MHz
Trigger Mode
Edge, Pulse, Video, Alternative
Trigger Source
CH1, CH2, CH3,CH4
Waveform Signal Process
,-,x,÷,FFT, Invert
Cursors Measurement
Cross, Trace, Horizontal, Vertical
Auto Measurement
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume
175mm * 105mm * 25mm
Weight
0.9KG

Biztonsági feltételek

Szállításii feltételek

Visszaküldési feltételek