ProductFunction:
 Set Temperature ---- SetT;
Backlash Temperature-----BackT;
1.  Heating Mode 'H':
 When Temperature ≤ SetT - BackT ;Relay conduction, heating equipment begin to work;
 When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;
2. Refrigeration mode 'C':
When Temperature ≥ SetT  BackT ;Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;
3. High Temperature Alarm 'ALA':
When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;
4. Delay Start ‘OPH':
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;
5. Temperature Correction FunctionOFE(-10.0 ~ 10.0°):
   The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured  Calibration;
6. Parameter Remote Read/Set:
   The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.   
7. Real-time Temperature Report:
   If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;
8. Relay enable (default enable):
If the relay is disable, the relay remains disconnected;
9. Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings;
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

XY-T01 digitális termosztát fűtés hűtés digitális hőmérséklet vezérlő kapcsoló hőmérséklet vezérlő modul LCD kijelző
XY-T01 Digital Thermostat Heating Refrigeration Digital Temperature Control Switch Temperature Controller Module LCD Display
ProductFunction:
 Set Temperature ---- SetT;
Backlash Temperature-----BackT;
1.  Heating Mode 'H':
 When Temperature ≤ SetT - BackT ;Relay conduction, heating equipment begin to work;
 When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;
2. Refrigeration mode 'C':
When Temperature ≥ SetT  BackT ;Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;
3. High Temperature Alarm 'ALA':
When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;
4. Delay Start ‘OPH':
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;
5. Temperature Correction FunctionOFE(-10.0 ~ 10.0°):
   The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured  Calibration;
6. Parameter Remote Read/Set:
   The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.   
7. Real-time Temperature Report:
   If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;
8. Relay enable (default enable):
If the relay is disable, the relay remains disconnected;
9. Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings;
1005003412606360 - modules
1005003412606360

Hasonló kategóriák mint 16 :

Reviews

Write your review

XY-T01 digitális termosztát fűtés hűtés digitális hőmérséklet vezérlő kapcsoló hőmérséklet vezérlő modul LCD

ProductFunction:
 Set Temperature ---- SetT;
Backlash Temperature-----BackT;
1.  Heating Mode 'H':
 When Temperature ≤ SetT - BackT ;Relay conduction, heating equipment begin to work;
 When Temperature ≥ SetT, Relay disconnect, heating equipment stop work;
2. Refrigeration mode 'C':
When Temperature ≥ SetT  BackT ;Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ SetT ;Relay conduction, refrigeration equipment stop work;
3. High Temperature Alarm 'ALA':
When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;
4. Delay Start ‘OPH':
When a normal heating or refrigeration work is done, the system starts to time T, and only after the T≥OPH, the system can carry out the next round of heating or refrigeration work;
5. Temperature Correction FunctionOFE(-10.0 ~ 10.0°):
   The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured  Calibration;
6. Parameter Remote Read/Set:
   The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART.   
7. Real-time Temperature Report:
   If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;
8. Relay enable (default enable):
If the relay is disable, the relay remains disconnected;
9. Restore factory Settings:
At the same time press the STOP, set key more than 3S, restore factory settings;