Product Features:
Product functions are mainly classified into two categories: temperature function and humidity function;
The temperature function is as follows:
1. Automatic recognition of working mode:
The system automatically recognizes the working mode according to the start temperature/stop temperature;
Starting temperature>stop temperature, cooling mode 'C'; starting temperature
2. Cooling mode:
When the detection temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the refrigeration equipment starts to work;
When the detected temperature is less than or equal to the stop temperature, the relay is turned off, the red indicator light is off, and the refrigeration equipment stops working;
3. Heating mode:
When the detection temperature is less than the start temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;
When the detected temperature is greater than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the heating device stops working
4. Temperature correction function OFE (-10.0 ~ 10.0℃):
The system works for a long time, and there may be deviations. Through this function, the actual temperature = measured temperature calibration value;
How to set the start/stop temperature:
1. In the running interface, press and hold the 'TM ' key for more than 3 seconds to enter the startup temperature setting interface. The test can be used to modify the parameters through the TM TM- keys. After the parameter modification is completed, wait 6 seconds to automatically exit and save;
2. In the running interface, press and hold the 'TM-' key for more than 3 seconds to enter the stop temperature setting interface. The test can be used to modify the parameters through the TM TM- keys. After the parameters are modified, wait for 6 seconds to automatically exit and save;
Humidity functions are as follows:
1. Automatic recognition of working mode:
The system automatically recognizes the working mode according to the start humidity/stop temperature;
Start humidity> stop humidity, dehumidification mode 'd'; start humidity
2. Dehumidification mode:
When detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification equipment starts to work;
When the detected humidity is less than or equal to the stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working;
3. Humidification mode:
When the detected humidity is less than the start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;
When detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working
4. Humidity correction function RH (-10.0 ~ 10.0℃):
The system works for a long time, and there may be deviations. Through this function, the actual humidity = measured humidity calibration value;
How to set start/stop humidity:
1. In the running interface, press and hold the 'RH ' key for more than 3 seconds to enter the start humidity setting interface. The test can be used to modify the parameters through the RH RH- key. After the parameters are modified, wait for 6 seconds to automatically exit and save;
2. In the running interface, press and hold the 'RH-' key for more than 3 seconds to enter the stop humidity setting interface. The test can be used to modify the parameters through the RH RH- key. After the parameters are modified, wait for 6 seconds to automatically exit and save;
Operation interface description:
Working mode display. After the start temperature/humidity, stop temperature/humidity and other parameters are set, the current mode ("H/C", "E/d") will be displayed in front of the temperature/humidity;
When any relay is turned on, the upper left corner of the interface displays "OUT". If the temperature relay is turned on, the temperature operating mode "H/C" flashes to indicate a reminder; if the humidity relay is turned on, the humidity operating mode "E" flashes /d", as a reminder;
Other functions:
1. Remote reading/setting of parameters:
You can set parameters such as start temperature/humidity, stop temperature/humidity, and temperature/humidity correction through UART;
2. Real-time reporting of temperature/humidity:
If the temperature/humidity report function is turned on, the product will detect the temperature/humidity and relay status at 1s intervals and transmit it to the terminal via UART, which is convenient for data collection;
3. Relay enable (open by default):
If the relay enable is turned off, the relay remains off;
How to modify the temperature/humidity correction value:
1. In the running interface, double-click the 'TM ' key to enter the correction value setting interface; the lower line displays the correction value type, and the upper line displays the specific value; (OFE: temperature correction value RH: humidity correction value)
2. At this time, short press the 'TM-' key to switch the parameter to be modified, and use the RH RH- key to modify the specific value; long-press and short-press are supported;
3. After the parameter modification is completed, double-click the 'TM ' key to exit the correction value setting interface and save the data;
How to turn on/off the relay enable switch:
In the running interface, short press the'TM-' key to turn on or off the temperature relay enable (on: turn on OFF: turn off). After returning to the running interface, if the temperature relay is off, the temperature symbol'℃' will flash, Reminder.
In the running interface, short press the'RH-' key to turn on or off the humidity relay enable (on: open OFF: close). After returning to the running interface, if the humidity relay is in the off state, the humidity symbol'% ' will flash, Reminder.