- -43%
Szín: csupasz tányér - C típusú USB-C PD2.0 3.0 TO DC USB csali gyorstöltés kioldó Poll detektor PD 5A 9v 12v 15v 20V
Szín: csupasz tányér - C típusú USB-C PD2.0 3.0 TO DC USB csali gyorstöltés kioldó Poll detektor PD 5A 9v 12v 15v 20V
479 Ft
43% megtakarítás
841 Ft
Nincs adó
Function is introduced
This product can trigger any voltage conforming to PD2.0 specification, voltage 3-20V, current 0-5a, after triggering, users can supply the back-end load test or use through USB base or self-welding cable.
Directions for use
After power-on, ZY12PDS will enter PD mode by default, and the steady red light indicates that the default 5V has been applied. If the adapter supports more voltage, you can click the switch to switch the output voltage, the colorful light on the stable red, yellow, green, blue, purple and white display the actual application suitable for the corresponding 1-7 voltage and current group output,
If the adapter does not support PD mode, the connection times out abnormally, or the application is not responded to, the seven color indicator blinks in red
Mode setting
When powering on, the colorful light will flash a color to indicate the current working mode. Press and hold the button to power on again. After the colorful light flashes quickly, let go and enter the setting.
7 color lamp color corresponding to function red, key switching voltage yellow, 8-10V green, 11-13V blue, 14-16V blue, 18-20V purple, the highest voltage white, polling all supported voltages.
Apply the highest voltage logic, assuming broadcast 5.9.20.15V apply 20V. Apply for the highest voltage value in the broadcast, if there are more than the same maximum value apply for the last one.
Apply fixed voltage logic: assume setting 14-16V. Broadcast 5.14.16.15.12V then apply 15V, apply the last voltage in the range of broadcast.
This product can trigger any voltage conforming to PD2.0 specification, voltage 3-20V, current 0-5a, after triggering, users can supply the back-end load test or use through USB base or self-welding cable.
Directions for use
After power-on, ZY12PDS will enter PD mode by default, and the steady red light indicates that the default 5V has been applied. If the adapter supports more voltage, you can click the switch to switch the output voltage, the colorful light on the stable red, yellow, green, blue, purple and white display the actual application suitable for the corresponding 1-7 voltage and current group output,
If the adapter does not support PD mode, the connection times out abnormally, or the application is not responded to, the seven color indicator blinks in red
Mode setting
When powering on, the colorful light will flash a color to indicate the current working mode. Press and hold the button to power on again. After the colorful light flashes quickly, let go and enter the setting.
7 color lamp color corresponding to function red, key switching voltage yellow, 8-10V green, 11-13V blue, 14-16V blue, 18-20V purple, the highest voltage white, polling all supported voltages.
Apply the highest voltage logic, assuming broadcast 5.9.20.15V apply 20V. Apply for the highest voltage value in the broadcast, if there are more than the same maximum value apply for the last one.
Apply fixed voltage logic: assume setting 14-16V. Broadcast 5.14.16.15.12V then apply 15V, apply the last voltage in the range of broadcast.
Biztonsági feltételek
Szállításii feltételek
Visszaküldési feltételek