Zöld-Új 2 az 1-ben Vízszivattyú Automatikus Vezérlő DC 12V Folyékony Szintérzékelő Kapcsoló Relé Modul Akvárium motorjához
Zöld-Új 2 az 1-ben Vízszivattyú Automatikus Vezérlő DC 12V Folyékony Szintérzékelő Kapcsoló Relé Modul Akvárium motorjához
1 288 Ft40% megtakarítás
2 147 Ft
Nincs adó
New 2 in 1 Pump Pour Water Automatic Controller DC 12V Liquid Level Sensor Switch Relay Module for Motor Fish Tank Waterhouse1: Simple and easy to understand2: Easy to use3: Standby current 9MA4: Working current 40MAdescribe:
New 2 in 1 Pump Pour Water Automatic Controller DC 12V Liquid Level Sensor Switch Relay Module for Motor Fish Tank Waterhouse 1: Simple and easy to understand 2: Easy to use 3: Standby current 9MA 4: Working current 40MA describe: 1 Working voltage: DC 12V (DC 10-15V) 2 Standby current 9MA 3 Working current 40MA 4 Dimensions: 44mm X 29mm X 19mm 5 Weight: 19 grams 6 Maximum load: 10A/250VAC, 10A/125VAC, 10A/30VDC, 10A/28VDC, 10A/12VDC There are two purposes for connecting the NO and NC ports of the relay: The water pump is connected to the automatic water injection tower at the COM NC port The water pump is connected to the COM NO port and automatically pumps water from the water tower notes: The probe (wire) is not included in the package. No need to use special probes, use household wires to make probes For safety, please use a well-isolated DC power supply application Automatic water supply system for household water tower Aquarium fish tank water changing system Automatic filling of water tower Automatic pumping of water tower Conductive liquid automatic control Automatic feeding system for poultry and livestock Farm automatic water supply system And other occasions that require automatic water supply and water change. Solenoid valve water pump motor automatic control Interface Description: HIGH: Upper limit probe OUT: output probe LOW: Lower limit probe DC+: positive power supply DC-: Negative power supply NC: Relay normally closed contact COM: Relay common contact NO: Relay normally open contact Working principle (automatic water injection tower): The water level rises: when the water level is lower than the "low level", the water pump starts to supply water to the water tower; when the water level is higher than the "high level", the water pump stops water supply. The water level drops: When the water level is lower than the "high level", the water pump does not work and the water level continues to drop. When the water level is lower than the "low water level", the water pump starts to supply water to the water tower. Working principle (automatic pumping of water tower): Contrary to "automatic filling of water tower" Checklist 1*controller module