Product Name: 2 in 1 RS485 & RS232(TTL) AT & Modbus RTU Relay Switch Board PC USB COM UART Serial port 1 Channel 12VDC Module
 
  
Package inlcuded:
 1 x DC 12V 1Ch RS485 Modbus & AT command  Relay Board
 
 
Description: 
 
1: DC 12V power supply
 
2: Standby current (all relays closed) 9MA, 1 relay open 41MA
 
3: ''Open'' ''Close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
 
4: Two instruction-control mode : AT command and MODBUS command
 
5: Under the AT command ,the maximum delay is 9999 seconds
    Under the MODBUS command ,the maximum delay is 255 seconds
 
6 AT commands can be made serial HyperTerminal (serial assistant) Enter;
   MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter;
 
7 Under the MODBUS command mode, it can support up to 247 devices in parallel
 
8 Size: 40 * 30 * 18mm ;
 
9 Weight: 18 g; 
 
10 Maximum load: 20A 14VDC;20A/125VAC;10A/250VAC
 
Instruction manual Please ask us after the purchase
 
 
Application
  
Automated industry PLC
Smart Home,Home Automation ;
Identification system;
Motor FW & BW;
CCTV Camera PTZ Control; 
Security system;
LED dot matrix screen;
 
  
  
Typical applications:
 
1 AT command mode (M0 Connect), in this mode can be through the serial HyperTerminal (serial assistant) enter a simple AT command control relay. AT command mode time up to 9999 seconds 
 
 
2 MODBUS command mode (M0 disconnect), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
Wiring Diagram:
 
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
 
2 DC 12V motor reversing control, Wiring diagram below. ''LOAD'' can be Fans, motors, pumps and other DC 12V equipment
 
 
 
 
Test Software(We offer a demo video):
  
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 
 
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

 
 
Product Name: 2 in 1 RS485 & RS232(TTL) AT & Modbus RTU Relay Switch Board PC USB COM UART Serial port 1 Channel 12VDC Module
 
  
Package inlcuded:
 1 x DC 12V 1Ch RS485 Modbus & AT command  Relay Board
 
 
Description: 
 
1: DC 12V power supply
 
2: Standby current (all relays closed) 9MA, 1 relay open 41MA
 
3: ''Open'' ''Close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
 
4: Two instruction-control mode : AT command and MODBUS command
 
5: Under the AT command ,the maximum delay is 9999 seconds
    Under the MODBUS command ,the maximum delay is 255 seconds
 
6 AT commands can be made serial HyperTerminal (serial assistant) Enter;
   MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter;
 
7 Under the MODBUS command mode, it can support up to 247 devices in parallel
 
8 Size: 40 * 30 * 18mm ;
 
9 Weight: 18 g; 
 
10 Maximum load: 20A 14VDC;20A/125VAC;10A/250VAC
 
Instruction manual Please ask us after the purchase
 
 
Application
  
Automated industry PLC
Smart Home,Home Automation ;
Identification system;
Motor FW & BW;
CCTV Camera PTZ Control; 
Security system;
LED dot matrix screen;
 
  
  
Typical applications:
 
1 AT command mode (M0 Connect), in this mode can be through the serial HyperTerminal (serial assistant) enter a simple AT command control relay. AT command mode time up to 9999 seconds 
 
 
2 MODBUS command mode (M0 disconnect), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
Wiring Diagram:
 
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
 
2 DC 12V motor reversing control, Wiring diagram below. ''LOAD'' can be Fans, motors, pumps and other DC 12V equipment
 
 
 
 
Test Software(We offer a demo video):
  
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 
 
32981275407 - shop1525466
32981275407

Hasonló kategóriák mint 16 :

Reviews

Write your review

2 az 1-ben RS485 és RS232(TTL) AT és Modbus RTU relé kapcsolókártya PC USB COM UART soros port 1 csatornás 12 VDC modul

 
 
Product Name: 2 in 1 RS485 & RS232(TTL) AT & Modbus RTU Relay Switch Board PC USB COM UART Serial port 1 Channel 12VDC Module
 
  
Package inlcuded:
 1 x DC 12V 1Ch RS485 Modbus & AT command  Relay Board
 
 
Description: 
 
1: DC 12V power supply
 
2: Standby current (all relays closed) 9MA, 1 relay open 41MA
 
3: ''Open'' ''Close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
 
4: Two instruction-control mode : AT command and MODBUS command
 
5: Under the AT command ,the maximum delay is 9999 seconds
    Under the MODBUS command ,the maximum delay is 255 seconds
 
6 AT commands can be made serial HyperTerminal (serial assistant) Enter;
   MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter;
 
7 Under the MODBUS command mode, it can support up to 247 devices in parallel
 
8 Size: 40 * 30 * 18mm ;
 
9 Weight: 18 g; 
 
10 Maximum load: 20A 14VDC;20A/125VAC;10A/250VAC
 
Instruction manual Please ask us after the purchase
 
 
Application
  
Automated industry PLC
Smart Home,Home Automation ;
Identification system;
Motor FW & BW;
CCTV Camera PTZ Control; 
Security system;
LED dot matrix screen;
 
  
  
Typical applications:
 
1 AT command mode (M0 Connect), in this mode can be through the serial HyperTerminal (serial assistant) enter a simple AT command control relay. AT command mode time up to 9999 seconds 
 
 
2 MODBUS command mode (M0 disconnect), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
Wiring Diagram:
 
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
 
2 DC 12V motor reversing control, Wiring diagram below. ''LOAD'' can be Fans, motors, pumps and other DC 12V equipment
 
 
 
 
Test Software(We offer a demo video):
  
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 
 