Product Name:  16-Channel 12V 10A DIN Rail Box PLC Expansion Board RS485 Modbus RTU Relay Module
 
 
 
Package inlcuded:
  1x DC 12V 16Ch DIN35 C45 Rail RS485 Modbus RTU Relay Board
 
 
Description: 
 
1: DC 12V power supply 
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 148MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA.etc
3: ''open'' ''close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
4: Two instruction-control mode : MODBUS RTU command and AT command
5: Under the ''Delay'' command ,the maximum delay is 255 seconds;
  Under the AT command ,the maximum delay is 9999 seconds
6 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter; AT commands can be made serial HyperTerminal (serial assistant) Enter;
7 Under the MODBUS command mode, it can support up to 64 devices in parallel
8 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
9  Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
10 Weight: 230g(Only PCB Board);358g(with Din Rail Box)
11 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
For more information, please contact me
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 180 mm PCB boards
Net weight: 128g
Installation: DIN35 OR C45 rail
   
 
 
  
Application
    
 
PLC expansion board
Smart Home,Home Automation ,Wiser Home;  
PTZ CCTV IP Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
LED  illumination
 
Typical applications:
1 When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
 
MODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
 
 
  
Wiring Diagram:
  
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
  
2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen
 
 
 
Test Software(We offer a demo video):
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

A cím elején, valamint az első képen szereplő szín/minta/méret/típus kerül kiszállításra!
 
Product Name:  16-Channel 12V 10A DIN Rail Box PLC Expansion Board RS485 Modbus RTU Relay Module
 
 
 
Package inlcuded:
  1x DC 12V 16Ch DIN35 C45 Rail RS485 Modbus RTU Relay Board
 
 
Description: 
 
1: DC 12V power supply 
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 148MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA.etc
3: ''open'' ''close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
4: Two instruction-control mode : MODBUS RTU command and AT command
5: Under the ''Delay'' command ,the maximum delay is 255 seconds;
  Under the AT command ,the maximum delay is 9999 seconds
6 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter; AT commands can be made serial HyperTerminal (serial assistant) Enter;
7 Under the MODBUS command mode, it can support up to 64 devices in parallel
8 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
9  Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
10 Weight: 230g(Only PCB Board);358g(with Din Rail Box)
11 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
For more information, please contact me
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 180 mm PCB boards
Net weight: 128g
Installation: DIN35 OR C45 rail
   
 
 
  
Application
    
 
PLC expansion board
Smart Home,Home Automation ,Wiser Home;  
PTZ CCTV IP Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
LED  illumination
 
Typical applications:
1 When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
 
MODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
 
 
  
Wiring Diagram:
  
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
  
2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen
 
 
 
Test Software(We offer a demo video):
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 
4000834191354/2 - shop1525466
4000834191354/2

Hasonló kategóriák mint 16 :

Reviews

Write your review

Szín: Din sínnel - 16 csatornás 12V 10A DIN síndoboz PLC bővítőkártya RS485 Modbus RTU relémodul

 
Product Name:  16-Channel 12V 10A DIN Rail Box PLC Expansion Board RS485 Modbus RTU Relay Module
 
 
 
Package inlcuded:
  1x DC 12V 16Ch DIN35 C45 Rail RS485 Modbus RTU Relay Board
 
 
Description: 
 
1: DC 12V power supply 
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 148MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA.etc
3: ''open'' ''close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands
4: Two instruction-control mode : MODBUS RTU command and AT command
5: Under the ''Delay'' command ,the maximum delay is 255 seconds;
  Under the AT command ,the maximum delay is 9999 seconds
6 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter; AT commands can be made serial HyperTerminal (serial assistant) Enter;
7 Under the MODBUS command mode, it can support up to 64 devices in parallel
8 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
9  Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
10 Weight: 230g(Only PCB Board);358g(with Din Rail Box)
11 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
For more information, please contact me
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 180 mm PCB boards
Net weight: 128g
Installation: DIN35 OR C45 rail
   
 
 
  
Application
    
 
PLC expansion board
Smart Home,Home Automation ,Wiser Home;  
PTZ CCTV IP Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
LED  illumination
 
Typical applications:
1 When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
 
MODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
 
 
 
  
Wiring Diagram:
  
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
 
 
 
  
2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen
 
 
 
Test Software(We offer a demo video):
Serial HyperTerminal:
  
Modbus Poll
 
 
 
 

Write your review