- -43%
Szín: - 2 az 1-ben 12CH Modbus RTU/TCP DIO hálózati Ethernet vezérlő RS485 relémodul DC 12V 24V
Szín: - 2 az 1-ben 12CH Modbus RTU/TCP DIO hálózati Ethernet vezérlő RS485 relémodul DC 12V 24V
3 958 Ft
43% megtakarítás
6 943 Ft
Nincs adó
Product Name: 2 in 1 12CH Modbus RTU/TCP DIO Network Ethernet Controller RS485 Relay Module DC 12V 24V
Package inlcuded:
1PCS DC 12V/24V 12Ch DIO RS485/Ethernet Modbus RTU Relay Board
Features:
1: DC 12V (12V Version), DC 24V (24V Version)
2: Standby current (DC 12V all relays closed) 14MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 149MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 226MA
3 12 photoelectric isolation Input ports (NPN low level active ), the input and output relationship can be set to associated (default) and non-associated through commands.
4: ''open'' ''close'' ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' ''''Interlock between two channels'' 7 Commands
5: MODBUS RTU command, Support 03 06 16 function code
6: Under the ''Delay'' command ,the maximum delay is 255 seconds;
7 :MODBUS commands can be made serial HyperTerminal (serial assistant) OR ''Modbus Poll'' Enter;
8 :Under the MODBUS command mode, it can support up to 64 devices in parallel
9 :The default baud rate is 9600BPS. The baud rate can be set by command: 2400 4800 9600 19200 38400 57600 115200BPS
10: The check methods can be none parity check, even parity check and odd parity check
11 :The data sending and returning time can be set, with a maximum value of 1000ms
12 :Size: 200 * 72 * 22mm(Only PCB Board);220 * 88* 46mm(with Din Rail Box)
13: Weight: 250.5g(Only PCB Board);382g(with Din Rail Box)
14: Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 200 mm PCB boards
Net weight:128g
Installation: DIN35 and C45 rail
Application
PLC Ethernet expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
Typical applications:
1 The dial switch (slave address) is invalid and can only control one module at a time.
2.MODBUS command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
Wiring Diagram:
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
2 DC 1-110VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipment
Package inlcuded:
1PCS DC 12V/24V 12Ch DIO RS485/Ethernet Modbus RTU Relay Board
Features:
1: DC 12V (12V Version), DC 24V (24V Version)
2: Standby current (DC 12V all relays closed) 14MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 149MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 226MA
3 12 photoelectric isolation Input ports (NPN low level active ), the input and output relationship can be set to associated (default) and non-associated through commands.
4: ''open'' ''close'' ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' ''''Interlock between two channels'' 7 Commands
5: MODBUS RTU command, Support 03 06 16 function code
6: Under the ''Delay'' command ,the maximum delay is 255 seconds;
7 :MODBUS commands can be made serial HyperTerminal (serial assistant) OR ''Modbus Poll'' Enter;
8 :Under the MODBUS command mode, it can support up to 64 devices in parallel
9 :The default baud rate is 9600BPS. The baud rate can be set by command: 2400 4800 9600 19200 38400 57600 115200BPS
10: The check methods can be none parity check, even parity check and odd parity check
11 :The data sending and returning time can be set, with a maximum value of 1000ms
12 :Size: 200 * 72 * 22mm(Only PCB Board);220 * 88* 46mm(with Din Rail Box)
13: Weight: 250.5g(Only PCB Board);382g(with Din Rail Box)
14: Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
DIN rail Box parameters:
Product model: UM72
Color: green
Width: suitable for PCB board width UM72(72mm)
Insulation grade: flame-retardant VO grade
Backplane length: suitable for 200 mm PCB boards
Net weight:128g
Installation: DIN35 and C45 rail
Application
PLC Ethernet expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
Typical applications:
1 The dial switch (slave address) is invalid and can only control one module at a time.
2.MODBUS command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
Wiring Diagram:
1 DC 12V control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V equipment
2 DC 1-110VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipment