• -43%

Szín: 2 utas 12V - 2 utas 5V/12V relé új modul optocsatolóval leválasztó relé bővítőkártyával

Szín: 2 utas 12V - 2 utas 5V/12V relé új modul optocsatolóval leválasztó relé bővítőkártyával

208 Ft 43% megtakarítás
365 Ft
Nincs adó
escription
1. The module uses genuine high-quality relays, the maximum load of the normally open interface: AC 250V/10A, DC 30V/10A;
2. Adopt SMD optocoupler isolation, strong driving ability, stable performance; trigger current 5mA;
3. The working voltage of the module has 5V, 12V to choose from;
4. The module can be triggered by a jumper to set high or low level;
5. Fault-tolerant design, even if the control line is broken, the relay will not act;
6. Power indicator (green), relay status indicator (red)
7. The interface design is user-friendly, all interfaces can be directly connected through the terminal block, which is very convenient
8. Module size: 50mm * 41mm* 18.5mm (length * width * height)
9. There are 4 fixing bolt holes, the hole is 3.1mm, and the spacing is 44.5mm*35.5mm
Two module interface:
1. DC : connect to the positive pole of the power supply (the voltage is according to the requirements of the relay, there are 5V.9V.12V and 24V options)
2. DC-: Connect to the negative pole of the power supply
3. IN1: 1 signal trigger terminal, you can set high or low level to control the relay to close
3. IN2: 2-channel signal trigger terminal, you can set high or low level to control the relay to close
Relay output:
1. NO1: 1 relay normally open interface, the relay is suspended before being closed, and short-circuited with COM1 after being closed
2. COM1: 1 relay common interface
3. NC1: 1 relay normally closed interface, short-circuit with COM1 before the relay is closed, and hang in the air after being closed
4. NO2: 2-way relay normally open interface, the relay is suspended before the pull-in, and short-circuited with COM2 after the pull-in
5. COM2: Common interface of 2 relays
6. NC2: 2-way relay normally closed interface, short-circuit with COM2 before the relay is closed, and hang in the air after being closed
3. Technical parameters:
Relay version Quiescent current Maximum current Trigger current Trigger voltage (low) High
5V 5mA 190mA 2-4mA 0-1.5V 2.5-5V
12V 5mA 80mA 2-4mA 0-4V 4.5-12V
High and low level trigger selection terminal:
1.S1 is the high and low level trigger selection of 1 relay;
2.S2 is the high and low level trigger selection of 2 relays;
3. When com and low are shorted, the corresponding relay is triggered at low level, and when com is shorted with high, it is triggered at high level
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

A cím elején, valamint az első képen szereplő szín/minta/méret/típus kerül kiszállításra!
2 utas 5V/12V relé új modul optocsatolóval leválasztó relé bővítőkártyával
2 Way 5V/12V Relay New Module With Optocoupler Isolation Relay Expansion Board Development Board
escription
1. The module uses genuine high-quality relays, the maximum load of the normally open interface: AC 250V/10A, DC 30V/10A;
2. Adopt SMD optocoupler isolation, strong driving ability, stable performance; trigger current 5mA;
3. The working voltage of the module has 5V, 12V to choose from;
4. The module can be triggered by a jumper to set high or low level;
5. Fault-tolerant design, even if the control line is broken, the relay will not act;
6. Power indicator (green), relay status indicator (red)
7. The interface design is user-friendly, all interfaces can be directly connected through the terminal block, which is very convenient
8. Module size: 50mm * 41mm* 18.5mm (length * width * height)
9. There are 4 fixing bolt holes, the hole is 3.1mm, and the spacing is 44.5mm*35.5mm
Two module interface:
1. DC : connect to the positive pole of the power supply (the voltage is according to the requirements of the relay, there are 5V.9V.12V and 24V options)
2. DC-: Connect to the negative pole of the power supply
3. IN1: 1 signal trigger terminal, you can set high or low level to control the relay to close
3. IN2: 2-channel signal trigger terminal, you can set high or low level to control the relay to close
Relay output:
1. NO1: 1 relay normally open interface, the relay is suspended before being closed, and short-circuited with COM1 after being closed
2. COM1: 1 relay common interface
3. NC1: 1 relay normally closed interface, short-circuit with COM1 before the relay is closed, and hang in the air after being closed
4. NO2: 2-way relay normally open interface, the relay is suspended before the pull-in, and short-circuited with COM2 after the pull-in
5. COM2: Common interface of 2 relays
6. NC2: 2-way relay normally closed interface, short-circuit with COM2 before the relay is closed, and hang in the air after being closed
3. Technical parameters:
Relay version Quiescent current Maximum current Trigger current Trigger voltage (low) High
5V 5mA 190mA 2-4mA 0-1.5V 2.5-5V
12V 5mA 80mA 2-4mA 0-4V 4.5-12V
High and low level trigger selection terminal:
1.S1 is the high and low level trigger selection of 1 relay;
2.S2 is the high and low level trigger selection of 2 relays;
3. When com and low are shorted, the corresponding relay is triggered at low level, and when com is shorted with high, it is triggered at high level
1005003096851175. - pingto
1005003096851175.

Hasonló kategóriák mint 16 :

Reviews

Write your review

Szín: 2 utas 12V - 2 utas 5V/12V relé új modul optocsatolóval leválasztó relé bővítőkártyával

escription
1. The module uses genuine high-quality relays, the maximum load of the normally open interface: AC 250V/10A, DC 30V/10A;
2. Adopt SMD optocoupler isolation, strong driving ability, stable performance; trigger current 5mA;
3. The working voltage of the module has 5V, 12V to choose from;
4. The module can be triggered by a jumper to set high or low level;
5. Fault-tolerant design, even if the control line is broken, the relay will not act;
6. Power indicator (green), relay status indicator (red)
7. The interface design is user-friendly, all interfaces can be directly connected through the terminal block, which is very convenient
8. Module size: 50mm * 41mm* 18.5mm (length * width * height)
9. There are 4 fixing bolt holes, the hole is 3.1mm, and the spacing is 44.5mm*35.5mm
Two module interface:
1. DC : connect to the positive pole of the power supply (the voltage is according to the requirements of the relay, there are 5V.9V.12V and 24V options)
2. DC-: Connect to the negative pole of the power supply
3. IN1: 1 signal trigger terminal, you can set high or low level to control the relay to close
3. IN2: 2-channel signal trigger terminal, you can set high or low level to control the relay to close
Relay output:
1. NO1: 1 relay normally open interface, the relay is suspended before being closed, and short-circuited with COM1 after being closed
2. COM1: 1 relay common interface
3. NC1: 1 relay normally closed interface, short-circuit with COM1 before the relay is closed, and hang in the air after being closed
4. NO2: 2-way relay normally open interface, the relay is suspended before the pull-in, and short-circuited with COM2 after the pull-in
5. COM2: Common interface of 2 relays
6. NC2: 2-way relay normally closed interface, short-circuit with COM2 before the relay is closed, and hang in the air after being closed
3. Technical parameters:
Relay version Quiescent current Maximum current Trigger current Trigger voltage (low) High
5V 5mA 190mA 2-4mA 0-1.5V 2.5-5V
12V 5mA 80mA 2-4mA 0-4V 4.5-12V
High and low level trigger selection terminal:
1.S1 is the high and low level trigger selection of 1 relay;
2.S2 is the high and low level trigger selection of 2 relays;
3. When com and low are shorted, the corresponding relay is triggered at low level, and when com is shorted with high, it is triggered at high level