The number of high-precision XY-T01 digital temperature controller thermostat cooling and heating module
Product Features:
1. Heating mode ‘H’:
When the detection temperature is ≤ set temperature-return temperature, the relay is turned on and the heating equipment starts to work;
 When the detected temperature is ≥ the set temperature, the relay is turned off and the heating equipment stops working;
2. Cooling mode ‘C’:
When the detection temperature ≥ set temperature hysteresis temperature, the relay is turned on and the refrigeration equipment starts to work;
When the detected temperature is ≤ the set temperature, the relay is turned off, and the refrigeration equipment stops working;
3. High temperature alarm function ALA:
     When the actual temperature is greater than or equal to the alarm temperature, the system will turn on the audible and visual alarm, and turn off the relay.
4. Delay start OPH:
When a normal heating or cooling work is completed, the system starts timing T. Only after T≥OPH can the system perform the next heating or cooling work;
5. Temperature correction function OFE (-10.0 ~ 10.0 ℃):
     The system may work for a long time, and there may be deviations. Through this function to correct, the actual temperature = measured temperature calibration value;
6. Remote parameter reading / setting:
     Can set the start temperature, stop temperature, temperature correction and other parameters through UART;
7. Real-time temperature reporting:
     If the temperature reporting function is turned on, the product transmits the detection temperature to the terminal through the UART at 1s intervals, which is convenient for data collection;
8. Relay enable (default on):
If the relay is turned off and enabled, the relay remains open;
9. Restore factory settings:
Simultaneously press the STOP and SET keys for more than 3S to restore the factory settings;
Working mode / set temperature / hypothesis temperature setting:
1. In the running interface, short press the SET key to enter the quick setting interface;
2. After entering the quick setting interface, short press the SET key to switch the parameter to be set (working mode / set temperature / backward temperature);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the quick setting interface, and save the parameters;
Alarm temperature / delay start setting / temperature correction:
1. In the operation interface, press and hold SET for more than 3s to enter the parameter setting interface;
2. After entering the parameter setting interface, short press the SET key to switch the parameter to be set (alarm temperature / delayed start setting / temperature correction);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the parameter setting interface, and save the parameters;
 
How to enable high temperature alarm (default off):
        Enter the parameter setting interface, switch to the alarm parameter ALA interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, ALA displays ‘----’ as a reminder;
How to enable delayed start (default off):
Enter the parameter setting interface, switch to the alarm parameter OPH interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, OPH displays ‘----’ as a reminder;
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

1 db XY-T01 digitális termosztát fűtés hűtés digitális hőmérséklet vezérlő kapcsoló hőmérséklet vezérlő modul
1PCS XY-T01 Digital Thermostat Heating Refrigeration Digital Temperature Control Switch Temperature Controller Module
 
The number of high-precision XY-T01 digital temperature controller thermostat cooling and heating module
Product Features:
1. Heating mode ‘H’:
When the detection temperature is ≤ set temperature-return temperature, the relay is turned on and the heating equipment starts to work;
 When the detected temperature is ≥ the set temperature, the relay is turned off and the heating equipment stops working;
2. Cooling mode ‘C’:
When the detection temperature ≥ set temperature hysteresis temperature, the relay is turned on and the refrigeration equipment starts to work;
When the detected temperature is ≤ the set temperature, the relay is turned off, and the refrigeration equipment stops working;
3. High temperature alarm function ALA:
     When the actual temperature is greater than or equal to the alarm temperature, the system will turn on the audible and visual alarm, and turn off the relay.
4. Delay start OPH:
When a normal heating or cooling work is completed, the system starts timing T. Only after T≥OPH can the system perform the next heating or cooling work;
5. Temperature correction function OFE (-10.0 ~ 10.0 ℃):
     The system may work for a long time, and there may be deviations. Through this function to correct, the actual temperature = measured temperature calibration value;
6. Remote parameter reading / setting:
     Can set the start temperature, stop temperature, temperature correction and other parameters through UART;
7. Real-time temperature reporting:
     If the temperature reporting function is turned on, the product transmits the detection temperature to the terminal through the UART at 1s intervals, which is convenient for data collection;
8. Relay enable (default on):
If the relay is turned off and enabled, the relay remains open;
9. Restore factory settings:
Simultaneously press the STOP and SET keys for more than 3S to restore the factory settings;
Working mode / set temperature / hypothesis temperature setting:
1. In the running interface, short press the SET key to enter the quick setting interface;
2. After entering the quick setting interface, short press the SET key to switch the parameter to be set (working mode / set temperature / backward temperature);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the quick setting interface, and save the parameters;
Alarm temperature / delay start setting / temperature correction:
1. In the operation interface, press and hold SET for more than 3s to enter the parameter setting interface;
2. After entering the parameter setting interface, short press the SET key to switch the parameter to be set (alarm temperature / delayed start setting / temperature correction);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the parameter setting interface, and save the parameters;
 
How to enable high temperature alarm (default off):
        Enter the parameter setting interface, switch to the alarm parameter ALA interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, ALA displays ‘----’ as a reminder;
How to enable delayed start (default off):
Enter the parameter setting interface, switch to the alarm parameter OPH interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, OPH displays ‘----’ as a reminder;
4001066529726 - aitex
4001066529726

Hasonló kategóriák mint 16 :

Reviews

Write your review

1 db XY-T01 digitális termosztát fűtés hűtés digitális hőmérséklet vezérlő kapcsoló hőmérséklet vezérlő modul

 
The number of high-precision XY-T01 digital temperature controller thermostat cooling and heating module
Product Features:
1. Heating mode ‘H’:
When the detection temperature is ≤ set temperature-return temperature, the relay is turned on and the heating equipment starts to work;
 When the detected temperature is ≥ the set temperature, the relay is turned off and the heating equipment stops working;
2. Cooling mode ‘C’:
When the detection temperature ≥ set temperature hysteresis temperature, the relay is turned on and the refrigeration equipment starts to work;
When the detected temperature is ≤ the set temperature, the relay is turned off, and the refrigeration equipment stops working;
3. High temperature alarm function ALA:
     When the actual temperature is greater than or equal to the alarm temperature, the system will turn on the audible and visual alarm, and turn off the relay.
4. Delay start OPH:
When a normal heating or cooling work is completed, the system starts timing T. Only after T≥OPH can the system perform the next heating or cooling work;
5. Temperature correction function OFE (-10.0 ~ 10.0 ℃):
     The system may work for a long time, and there may be deviations. Through this function to correct, the actual temperature = measured temperature calibration value;
6. Remote parameter reading / setting:
     Can set the start temperature, stop temperature, temperature correction and other parameters through UART;
7. Real-time temperature reporting:
     If the temperature reporting function is turned on, the product transmits the detection temperature to the terminal through the UART at 1s intervals, which is convenient for data collection;
8. Relay enable (default on):
If the relay is turned off and enabled, the relay remains open;
9. Restore factory settings:
Simultaneously press the STOP and SET keys for more than 3S to restore the factory settings;
Working mode / set temperature / hypothesis temperature setting:
1. In the running interface, short press the SET key to enter the quick setting interface;
2. After entering the quick setting interface, short press the SET key to switch the parameter to be set (working mode / set temperature / backward temperature);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the quick setting interface, and save the parameters;
Alarm temperature / delay start setting / temperature correction:
1. In the operation interface, press and hold SET for more than 3s to enter the parameter setting interface;
2. After entering the parameter setting interface, short press the SET key to switch the parameter to be set (alarm temperature / delayed start setting / temperature correction);
3. Modify the parameter value by UP DOWN key, support short / long press;
4. Press and hold SET for more than 3S or continue for 6S without any key operation, exit the parameter setting interface, and save the parameters;
 
How to enable high temperature alarm (default off):
        Enter the parameter setting interface, switch to the alarm parameter ALA interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, ALA displays ‘----’ as a reminder;
How to enable delayed start (default off):
Enter the parameter setting interface, switch to the alarm parameter OPH interface, and press the STOP key to turn the high temperature alarm function on or off; if the high temperature alarm function is turned off, OPH displays ‘----’ as a reminder;