• -43%

XH-M214 12V talajnedvesség érzékelő vezérlő öntözőrendszer automatikus öntözési modul digitális kijelző

XH-M214 12V talajnedvesség érzékelő vezérlő öntözőrendszer automatikus öntözési modul digitális kijelző

320 Ft 43% megtakarítás
561 Ft
Nincs adó
Description:
The probe can be inserted directly into the soil. It is a digital display of soil moisture. When the humidity is below the set value starting pump starts watering, when humidity reaches the set value to stop watering. The operation is very simple. It is intelligent humanization.
Parameters:
Product name: Soil Moisture Controller Module
Model: XH - M214
Power supply voltage: DC 12 V
Output way: Output switch
Humidity range: 20-99% RH
Control precision: 1% RH
Control current: 10 A
Size: 52 * 43 * 16 mm
Using attention:
Please follow the wiring diagram of the description. You can choose the appropriate wiring mode according to the load voltage you use
1>. F0 setting start humidity(the humidity of the solenoid valve or the pump start working)Press the “SET” button to display “F0” and press the “SET” button to display the start humidity, and press / button to “SET” the humidity value
2>. F1 setting stop humidity (the humidity of the solenoid valve or the pump stops working)Press /- button to switch to “F1”, press the “SET” button to display the stop humidity value, and press / button to SET the humidity value
3>. F2 humidity correction
Normal use without correction error.The correction of values in the use of multiple modules at the same time is conducive to a unified management operation.
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

XH-M214 12V talajnedvesség érzékelő vezérlő öntözőrendszer automatikus öntözési modul digitális kijelző páratartalom szabályozó
XH-M214 12V Soil Humidity Sensor Controller Irrigation System Automatic Watering Module Digital Display Humidity Controller
Description:
The probe can be inserted directly into the soil. It is a digital display of soil moisture. When the humidity is below the set value starting pump starts watering, when humidity reaches the set value to stop watering. The operation is very simple. It is intelligent humanization.
Parameters:
Product name: Soil Moisture Controller Module
Model: XH - M214
Power supply voltage: DC 12 V
Output way: Output switch
Humidity range: 20-99% RH
Control precision: 1% RH
Control current: 10 A
Size: 52 * 43 * 16 mm
Using attention:
Please follow the wiring diagram of the description. You can choose the appropriate wiring mode according to the load voltage you use
1>. F0 setting start humidity(the humidity of the solenoid valve or the pump start working)Press the “SET” button to display “F0” and press the “SET” button to display the start humidity, and press / button to “SET” the humidity value
2>. F1 setting stop humidity (the humidity of the solenoid valve or the pump stops working)Press /- button to switch to “F1”, press the “SET” button to display the stop humidity value, and press / button to SET the humidity value
3>. F2 humidity correction
Normal use without correction error.The correction of values in the use of multiple modules at the same time is conducive to a unified management operation.
1005003693986233 - pngto
1005003693986233

Hasonló kategóriák mint 16 :

Reviews

Write your review

XH-M214 12V talajnedvesség érzékelő vezérlő öntözőrendszer automatikus öntözési modul digitális kijelző

Description:
The probe can be inserted directly into the soil. It is a digital display of soil moisture. When the humidity is below the set value starting pump starts watering, when humidity reaches the set value to stop watering. The operation is very simple. It is intelligent humanization.
Parameters:
Product name: Soil Moisture Controller Module
Model: XH - M214
Power supply voltage: DC 12 V
Output way: Output switch
Humidity range: 20-99% RH
Control precision: 1% RH
Control current: 10 A
Size: 52 * 43 * 16 mm
Using attention:
Please follow the wiring diagram of the description. You can choose the appropriate wiring mode according to the load voltage you use
1>. F0 setting start humidity(the humidity of the solenoid valve or the pump start working)Press the “SET” button to display “F0” and press the “SET” button to display the start humidity, and press / button to “SET” the humidity value
2>. F1 setting stop humidity (the humidity of the solenoid valve or the pump stops working)Press /- button to switch to “F1”, press the “SET” button to display the stop humidity value, and press / button to SET the humidity value
3>. F2 humidity correction
Normal use without correction error.The correction of values in the use of multiple modules at the same time is conducive to a unified management operation.

Write your review