• -43%

Szín: 24V - DC 5V/12V/24V fotoellenállás relé érzékelő fényvezérlő kapcsoló fényérzékelő vezérlőmodul nélkül

Szín: 24V - DC 5V/12V/24V fotoellenállás relé érzékelő fényvezérlő kapcsoló fényérzékelő vezérlőmodul nélkül

197 Ft 43% megtakarítás
346 Ft
Nincs adó
escription
A functional characteristic

1. The photoresistor is used to sense the intensity of light, and it comes with genuine high-quality relays, which can directly control AC or DC loads.

Maximum load capacity of normally open interface: AC 0V-250V/10A, DC 0V--30V/10A;
2
, The sensitivity can be adjusted by the potentiometer, and the threshold of the start relay can be set by adjusting the potentiometer. When it is darker than this threshold, the module relay is closed, and when it is brighter than this threshold, the relay is released;

Intelligent adjustment design, when the relay is activated, automatically fine-tune the action threshold, which solves the problem of repeated actions of the critical value;
4. The module has the function of anti-reverse connection, and the reverse connection of the power supply will not damage the module;
5. Equipped with power indicator (red) and relay status indicator (blue)
6. There are 4 fixing bolt holes for easy installation;
7. Module size:
5.0cm*3.0cm*1.8cm;




Two instructions for use

1. The photoresistor module is sensitive to ambient light and is generally used to detect changes in the brightness of the ambient light;

2. When the module's ambient light is darker than the set threshold, the relay is closed, and the common end is connected to the normally open end (disconnected from the normally closed end). When the ambient light is brighter than the set threshold, the relay is turned off, and the common end Disconnect with the normally open terminal (connect with the normally closed terminal);

3. The three ports of common, normally open, and normally closed are equivalent to a dual-control switch. When the relay coil is energized, the common end and the normally open end are connected, and when there is no power, the common end and the normally closed end are connected;
Three electrical parameters

Working current: less than 90mA at 5V (less than 5mA when the relay is not operating)

Less than 50mA at 12V (less than 5mA when the relay is not operating)

Less than 30mA at 24V (less than 5mA when the relay is not operating)

Working temperature: recommended -20℃—60℃ (limit working temperature range -30℃—70℃)

Load capacity: the maximum load capacity of the relay normally open port: DC 0-30V/10A, AC 0-250V/10A

Maximum load capacity of relay normally closed port: DC 0-28V/10A, AC 0-125V/10A
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

A cím elején, valamint az első képen szereplő szín/minta/méret/típus kerül kiszállításra!
DC 5V/12V/24V fotoellenállás relé érzékelő fényvezérlő kapcsoló fényérzékelő vezérlőmodul nélkül
DC 5V/12V/24V Photoresistor Relay Sensor Light Control Switch Without Light Sensor Control Module
escription
A functional characteristic

1. The photoresistor is used to sense the intensity of light, and it comes with genuine high-quality relays, which can directly control AC or DC loads.

Maximum load capacity of normally open interface: AC 0V-250V/10A, DC 0V--30V/10A;
2
, The sensitivity can be adjusted by the potentiometer, and the threshold of the start relay can be set by adjusting the potentiometer. When it is darker than this threshold, the module relay is closed, and when it is brighter than this threshold, the relay is released;

Intelligent adjustment design, when the relay is activated, automatically fine-tune the action threshold, which solves the problem of repeated actions of the critical value;
4. The module has the function of anti-reverse connection, and the reverse connection of the power supply will not damage the module;
5. Equipped with power indicator (red) and relay status indicator (blue)
6. There are 4 fixing bolt holes for easy installation;
7. Module size:
5.0cm*3.0cm*1.8cm;




Two instructions for use

1. The photoresistor module is sensitive to ambient light and is generally used to detect changes in the brightness of the ambient light;

2. When the module's ambient light is darker than the set threshold, the relay is closed, and the common end is connected to the normally open end (disconnected from the normally closed end). When the ambient light is brighter than the set threshold, the relay is turned off, and the common end Disconnect with the normally open terminal (connect with the normally closed terminal);

3. The three ports of common, normally open, and normally closed are equivalent to a dual-control switch. When the relay coil is energized, the common end and the normally open end are connected, and when there is no power, the common end and the normally closed end are connected;
Three electrical parameters

Working current: less than 90mA at 5V (less than 5mA when the relay is not operating)

Less than 50mA at 12V (less than 5mA when the relay is not operating)

Less than 30mA at 24V (less than 5mA when the relay is not operating)

Working temperature: recommended -20℃—60℃ (limit working temperature range -30℃—70℃)

Load capacity: the maximum load capacity of the relay normally open port: DC 0-30V/10A, AC 0-250V/10A

Maximum load capacity of relay normally closed port: DC 0-28V/10A, AC 0-125V/10A
1005003101679952/3 - pngto
1005003101679952/3

Hasonló kategóriák mint 16 :

Reviews

Write your review

Szín: 24V - DC 5V/12V/24V fotoellenállás relé érzékelő fényvezérlő kapcsoló fényérzékelő vezérlőmodul nélkül

escription
A functional characteristic

1. The photoresistor is used to sense the intensity of light, and it comes with genuine high-quality relays, which can directly control AC or DC loads.

Maximum load capacity of normally open interface: AC 0V-250V/10A, DC 0V--30V/10A;
2
, The sensitivity can be adjusted by the potentiometer, and the threshold of the start relay can be set by adjusting the potentiometer. When it is darker than this threshold, the module relay is closed, and when it is brighter than this threshold, the relay is released;

Intelligent adjustment design, when the relay is activated, automatically fine-tune the action threshold, which solves the problem of repeated actions of the critical value;
4. The module has the function of anti-reverse connection, and the reverse connection of the power supply will not damage the module;
5. Equipped with power indicator (red) and relay status indicator (blue)
6. There are 4 fixing bolt holes for easy installation;
7. Module size:
5.0cm*3.0cm*1.8cm;




Two instructions for use

1. The photoresistor module is sensitive to ambient light and is generally used to detect changes in the brightness of the ambient light;

2. When the module's ambient light is darker than the set threshold, the relay is closed, and the common end is connected to the normally open end (disconnected from the normally closed end). When the ambient light is brighter than the set threshold, the relay is turned off, and the common end Disconnect with the normally open terminal (connect with the normally closed terminal);

3. The three ports of common, normally open, and normally closed are equivalent to a dual-control switch. When the relay coil is energized, the common end and the normally open end are connected, and when there is no power, the common end and the normally closed end are connected;
Three electrical parameters

Working current: less than 90mA at 5V (less than 5mA when the relay is not operating)

Less than 50mA at 12V (less than 5mA when the relay is not operating)

Less than 30mA at 24V (less than 5mA when the relay is not operating)

Working temperature: recommended -20℃—60℃ (limit working temperature range -30℃—70℃)

Load capacity: the maximum load capacity of the relay normally open port: DC 0-30V/10A, AC 0-250V/10A

Maximum load capacity of relay normally closed port: DC 0-28V/10A, AC 0-125V/10A

Write your review