- -43%
Nincs szín - RF teljesítménymérő -75 ~ 16 dBm 1-600MHz csillapítási érték SMA_K kimeneti interfész
Nincs szín - RF teljesítménymérő -75 ~ 16 dBm 1-600MHz csillapítási érték SMA_K kimeneti interfész
1 483 Ft
43% megtakarítás
2 602 Ft
Nincs adó
Features:
Measuring power range -75 ~ 16 dBm (external RF attenuator can be extended to 100dBm).
Measuring power resolution 0.1 dBm.
Measuring frequency range 1 ~ 600 MHz.
Output interface SMA_K.
Working voltage 6 ~ 12 VDC.
Operating current <45 mA (backlight on).
Operating temperature -40 â„ ~ 65 â„.
Storage temperature -40 â„ ~ 65 â„.
Interface display and operating instructions:
1 The main display shows the first line RF Power Meter
The second line shows the P power dBm; AT attenuation dB
The main menu can not be adjusted for measurement results
2 Function Menu:A The attenuation setting menu:The first line shows the Attenuation Menu
The second line shows ATTN: XXdB
To enter the menu function key: long press ENTER and then press ENTER SUB to execute , - operation
B Internal Compensation Set:The first row of ADC Offset Menu
The second line Offset: /- xx
To enter the menu function key: Press ADD SUB ENTER at the same time to exit ADD SUB to execute , - operation
C, automatic backlight function: to open the backlight by pressing any button when without backlight.
Package Included:
1 x RF Power Meter
Notice:
1. Due to the light and screen difference, the item's color may be slightly different from the pictures.
2. Please allow 0.5-2 cm differences due to manual measurement.Thank you for your kindly understanding
Measuring power range -75 ~ 16 dBm (external RF attenuator can be extended to 100dBm).
Measuring power resolution 0.1 dBm.
Measuring frequency range 1 ~ 600 MHz.
Output interface SMA_K.
Working voltage 6 ~ 12 VDC.
Operating current <45 mA (backlight on).
Operating temperature -40 â„ ~ 65 â„.
Storage temperature -40 â„ ~ 65 â„.
Interface display and operating instructions:
1 The main display shows the first line RF Power Meter
The second line shows the P power dBm; AT attenuation dB
The main menu can not be adjusted for measurement results
2 Function Menu:A The attenuation setting menu:The first line shows the Attenuation Menu
The second line shows ATTN: XXdB
To enter the menu function key: long press ENTER and then press ENTER SUB to execute , - operation
B Internal Compensation Set:The first row of ADC Offset Menu
The second line Offset: /- xx
To enter the menu function key: Press ADD SUB ENTER at the same time to exit ADD SUB to execute , - operation
C, automatic backlight function: to open the backlight by pressing any button when without backlight.
Package Included:
1 x RF Power Meter
Notice:
1. Due to the light and screen difference, the item's color may be slightly different from the pictures.
2. Please allow 0.5-2 cm differences due to manual measurement.Thank you for your kindly understanding
Biztonsági feltételek
Szállításii feltételek
Visszaküldési feltételek