• -43%

6-30V Micro USB digitális LCD kijelző időkésleltetés relé modul vezérlő időzítő kapcsoló trigger ciklus modul XY

6-30V Micro USB digitális LCD kijelző időkésleltetés relé modul vezérlő időzítő kapcsoló trigger ciklus modul XY

518 Ft 43% megtakarítás
909 Ft
Nincs adó
Product Description
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure.

1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support high and low level trigger, switch value control, suitable for most occasions;
3. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use;
4. Support UART data upload and parameter setting;
5. There is a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
6. Added sleep mode. After enabling, without any operation within 5 minutes, the LCD backlight will be automatically turned off; any keystroke will wake up;
7. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
8. All setting parameters are automatically saved after power-off.
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure. The timing range is 0.01 second (minimum) to 9999 minutes (maximum) continuously adjustable. How to choose the timing range: In the OP/CL parameter modification interface, short press the STOP button to select the timing range; XXXX has no decimal point, and the timing range is 1 second to 9999 seconds XXX .X The decimal point is in the tens place, the timing range is 0.1 second to 999.9 seconds XX.XX The decimal point is in the hundreds place, the timing range is 0.01 second to 99.99 seconds XXXX decimal point is all on, and the timing range is 1 minute to 9999 minutes. Then move the decimal point to the tens place, and the LCD will display 003.2. Parameter description: OP on time, CL off time, LOP cycle times (1—9999 times, "----" represents infinite cycles)
(1). Parameter setting
a) Long press the SET key to enter the setting interface;
b) First set the working mode, the working mode flashes to remind, shortly press the UP/DOWN key to set the working mode;
c) Short press the SET key to select the working mode and enter the system parameter setting;
d) In the system parameter setting interface, short press the SET key to switch the system parameters to be modified, short press/long press the UP/DOWN key to modify; (Note: short press in P-1~P-3, P-7 mode SET is invalid); e) In the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min); f) After setting all parameters, press and hold the SET key to save the parameter settings and exit the setting interface;
(3) Additional functions
a) Automatic sleep function: In the running interface, long press the STOP button to start or close the automatic sleep function (L-P selects on to start the sleep function, and off to close the sleep function);
b) Relay function selection: In the running interface, short press the STOP button to start or close the relay function,'on' meets the conduction condition and the relay is normally turned on,'OFF' meets the conduction condition and the relay is not turned on;'OFF' In the state, the system flashes'OUT';
c) Parameter view: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
d) Display content switching: In P-5 P-6 mode, short press the DOWN key to switch the display content (operating time/cycle times);
The system supports UART data upload and parameter setting function (TTL level); UART: 9600, 8, 1
Mennyiség

 

Biztonsági feltételek

 

Szállításii feltételek

 

Visszaküldési feltételek

6-30V Micro USB digitális LCD kijelző időkésleltetés relé modul vezérlő időzítő kapcsoló trigger ciklus modul XY-LJ02
6-30V Micro USB Digital LCD Display Time Delay Relay Module Control Timer Switch Trigger Cycle Module XY-LJ02
Product Description
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure.

1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support high and low level trigger, switch value control, suitable for most occasions;
3. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use;
4. Support UART data upload and parameter setting;
5. There is a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
6. Added sleep mode. After enabling, without any operation within 5 minutes, the LCD backlight will be automatically turned off; any keystroke will wake up;
7. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
8. All setting parameters are automatically saved after power-off.
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure. The timing range is 0.01 second (minimum) to 9999 minutes (maximum) continuously adjustable. How to choose the timing range: In the OP/CL parameter modification interface, short press the STOP button to select the timing range; XXXX has no decimal point, and the timing range is 1 second to 9999 seconds XXX .X The decimal point is in the tens place, the timing range is 0.1 second to 999.9 seconds XX.XX The decimal point is in the hundreds place, the timing range is 0.01 second to 99.99 seconds XXXX decimal point is all on, and the timing range is 1 minute to 9999 minutes. Then move the decimal point to the tens place, and the LCD will display 003.2. Parameter description: OP on time, CL off time, LOP cycle times (1—9999 times, "----" represents infinite cycles)
(1). Parameter setting
a) Long press the SET key to enter the setting interface;
b) First set the working mode, the working mode flashes to remind, shortly press the UP/DOWN key to set the working mode;
c) Short press the SET key to select the working mode and enter the system parameter setting;
d) In the system parameter setting interface, short press the SET key to switch the system parameters to be modified, short press/long press the UP/DOWN key to modify; (Note: short press in P-1~P-3, P-7 mode SET is invalid); e) In the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min); f) After setting all parameters, press and hold the SET key to save the parameter settings and exit the setting interface;
(3) Additional functions
a) Automatic sleep function: In the running interface, long press the STOP button to start or close the automatic sleep function (L-P selects on to start the sleep function, and off to close the sleep function);
b) Relay function selection: In the running interface, short press the STOP button to start or close the relay function,'on' meets the conduction condition and the relay is normally turned on,'OFF' meets the conduction condition and the relay is not turned on;'OFF' In the state, the system flashes'OUT';
c) Parameter view: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
d) Display content switching: In P-5 P-6 mode, short press the DOWN key to switch the display content (operating time/cycle times);
The system supports UART data upload and parameter setting function (TTL level); UART: 9600, 8, 1
1005003308308006. - pingto
1005003308308006.

Hasonló kategóriák mint 16 :

Reviews

Write your review

6-30V Micro USB digitális LCD kijelző időkésleltetés relé modul vezérlő időzítő kapcsoló trigger ciklus modul XY

Product Description
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure.

1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support high and low level trigger, switch value control, suitable for most occasions;
3. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use;
4. Support UART data upload and parameter setting;
5. There is a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
6. Added sleep mode. After enabling, without any operation within 5 minutes, the LCD backlight will be automatically turned off; any keystroke will wake up;
7. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
8. All setting parameters are automatically saved after power-off.
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high level trigger (3.0V~24V), low level trigger (0.0V~0.2V), switch control (passive switch).
3: Output capacity: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 8.0*3.8*1.9cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure. The timing range is 0.01 second (minimum) to 9999 minutes (maximum) continuously adjustable. How to choose the timing range: In the OP/CL parameter modification interface, short press the STOP button to select the timing range; XXXX has no decimal point, and the timing range is 1 second to 9999 seconds XXX .X The decimal point is in the tens place, the timing range is 0.1 second to 999.9 seconds XX.XX The decimal point is in the hundreds place, the timing range is 0.01 second to 99.99 seconds XXXX decimal point is all on, and the timing range is 1 minute to 9999 minutes. Then move the decimal point to the tens place, and the LCD will display 003.2. Parameter description: OP on time, CL off time, LOP cycle times (1—9999 times, "----" represents infinite cycles)
(1). Parameter setting
a) Long press the SET key to enter the setting interface;
b) First set the working mode, the working mode flashes to remind, shortly press the UP/DOWN key to set the working mode;
c) Short press the SET key to select the working mode and enter the system parameter setting;
d) In the system parameter setting interface, short press the SET key to switch the system parameters to be modified, short press/long press the UP/DOWN key to modify; (Note: short press in P-1~P-3, P-7 mode SET is invalid); e) In the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min); f) After setting all parameters, press and hold the SET key to save the parameter settings and exit the setting interface;
(3) Additional functions
a) Automatic sleep function: In the running interface, long press the STOP button to start or close the automatic sleep function (L-P selects on to start the sleep function, and off to close the sleep function);
b) Relay function selection: In the running interface, short press the STOP button to start or close the relay function,'on' meets the conduction condition and the relay is normally turned on,'OFF' meets the conduction condition and the relay is not turned on;'OFF' In the state, the system flashes'OUT';
c) Parameter view: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;
d) Display content switching: In P-5 P-6 mode, short press the DOWN key to switch the display content (operating time/cycle times);
The system supports UART data upload and parameter setting function (TTL level); UART: 9600, 8, 1

Write your review